Key Features

Multi-functional design 6 parameters in one meter  

  • Ready to test immediately   
  • Large display with bright LCD backlit, easy to read numbers  
  • The robust design lies in the palm of the hand perfectly   
  • Higher accuracy, greater precision   
  • Backlit display.   
  • Up to 1,000 memory sets with date & time and 7, 14, 21, 28, 60, 90 days average for tracking health conditions
  • Strip ejector design reduces the possibility of cross-infection  
  • Bluetooth 4.0 enabled, connect wirelessly to the iFORA® HM App and easy to use additional functions

Daily records, average & weekly lifestyle review

 

 

 

 

 

 

 

Strips

 

 
FORA 6 Test Strips

Blood Glucose

BG/HCT/HB

β-Ketone

Uric Acid

Total Cholesterol

Enzyme Type GDH-FAD GDH-FAD β-Hydroxybutyrate Dehydrogenase Uric Acid Catalyst Cholesterol esteraseCholesterol oxidase
Sample Size 0.5μL 0.5μL 0.8μL 1.0μL 3.0μL
Reaction Time 5 Seconds 5 Seconds 10 Seconds 15 Seconds 120 Seconds
Hematocrit Range 0 ~ 70% 0 ~ 70% 10 ~ 70% 20 ~ 60% 20 ~ 60%
Measuring Range 10 ~ 600 mg/dL (0.55 ~ 33.3 mmol/L) HB: 0 ~ 23.8 g/dL 0.1 ~ 8.0 mmol/L 3 ~ 20 mg/dL (0.179~1.190 mmol/L) 100 ~ 400 mg/dL
Precision < 100 mg/dL, SD < ± 5
≥100 mg/dL, CV < 5%
< 100 mg/dL, SD < ± 5≥100 mg/dL, CV < 5% ≤1mmol/L, SD<0.1mM >1mmol/L, CV<7.5% CV<7.5% CV<7.5%
AST[1] YES YES N/A YES N/A
Applicable Sample (Whole Blood) Capillary whole blood from fingertips; Venous; Arterial; neonatal Capillary whole blood from fingertips; Venous; Arterial; neonatal Capillary whole blood; Venous whole blood Capillary; Venous Capillary whole blood from fingertips
Applicable for General Patients; Dialysis patients; Gestational diabetes; Neonatal General Patients; Dialysis patients; Gestational diabetes; Neonatal General Patients; Dialysis patients; Gestational diabetes; General Patients; Dialysis patients; Gout patients General Patients; obesity
Code Type NO Code NO Code Code Card Code Card Code Card
[1] Alternative site testing (AST) means that people use parts of the body other than the fingertips to check their blood glucose levels. This system allows you to test on the palm, forearm, upper arm, forearm, thing or calf with the equivalent results to fingertip testing.

 

 

Superior Sip-in Technology

Blood application made easier and faster with a light touch. Supported by our Superior Sip-in (SSI) technology, it allows blood to be easily drawn out onto the absorbent area of the strip even when moving. This reduces the chances of strip wastage and boosts accurate glucose detection.

Lancing

New Lancing Comfort

Minimal cutaneous damage is achieved through a tri-bevel needle design and minimal needle-tip vibration during skin penetration.

 

 

Specifications

 

Key Features Sample Size (μL) 0.5μL FORA Blood Glucose or a 3-in-1 test
0.8μL for a β-Ketone test
1.0μL for a uric acid test
3.0μL for a total cholesterol test
Reaction Time 5 Seconds FORA Blood Glucose or a 3-in-1 test
10 Seconds for a β-Ketone test
15 Seconds for a uric acid test
2 minutes for a total cholesterol test
Hematocrit Range 20~60%
BG Measuring Range 0~700mg/dL (0~38.9mmol/L)
Advanced Features Memory 1,000 results with date and time
Talking Function N/A
Strip Ejection Yes
Strip Feed Light Yes
Daily Alarm 4 Sets
AST technology Applicable for BG, 3-in-1 and Uric Acid test strips
Auto sample loading Yes
Ketone Warning Yes ≧ 240mg/dL (13.3 mmol/L).
AC/PC in Memory Yes
QC Record Yes
Day Average 7/14/21/28/60/90 days
LCD Backlight N/A
Power Source Power Source 1.5V AAA battery *1
  Battery life At least 1,000 tests
  Power Saving 180 seconds. Auto turn-off if idle for three minutes
  Dimension 89.8(H) * 54.9(W) * 18.0(D) mm
  Weight 64.1g (without battery)
Environmental Requirements
  • Operating conditions 10oC to 40oC (50oF to 104oF), below 85% R.H. (no condensing)
  • Storage conditions -20oC to 60oC (-4oF to 140oF), 95% R.H.

FAQs

Q. What can I do when the meter shows “Error message” on the screen?

Error message:E-b/ Err 36

Battery power is too low to operate the meter. The meter will not operate until the batteries are replaced.
Solution: You have to replace or charge the batteries soon.

Error message: E-C/ Err 22

Invalid code strip insertion. E.g. get wrong test strip, defective test strip.

Solution: Only use the same brand strips which were produced specifically for your glucose monitor.

Error message: E-U/ Err 24

Inserts a used test strip. Repeat the test with a new test strip. Blood sample is input before the symbol for blood blinks.
Solution: Wait for the "blood drop" symbol to blink then re-test using a proper amount of blood.

Error message: E-t/ Err25

The meter or test strip appears when the environmental temperature is below system operating range. System operation range is 10~40℃.
Solution: Repeat the test after the meter or test strip has reached the above temperature.

Error message: E-t/ Err 26

The meter or test strip show on the screen when the environmental temperature is above system operating range. System operation range is 10~40℃.

Solution: Repeat the test after the meter or test strip has reached the above temperature.

Error message: E-F

Strip was removed soon after applying blood and not given enough time to be absorbed by the absorption hole.

Solution: Repeat the test with a new test strip and wait for the test result.

Error message: Lo

Poor amount of blood sample or blood glucose value under measurement range 20 mg/dL (1.1mmol/l).

Solution: Get a sufficient amount of blood sample and repeat the test with a new test strip. Blood glucose measurement range is 1.1~33.3 mmol/L. Repeat the test and seek immediate medical attention.

Error message: Hi

Blood glucose value over measurement range 33.3mmol/L.

Solution: Get a sufficient amount of blood sample and repeat the test with a new test strip. Blood glucose measurement range is 1.1~33.3 mmol/L. Repeat the test and seek immediate medical attention.

Other error messages

The meter may have some defective problems.
Solution: Repeat the test with a new test strip or repeat the measurement. If the error message appears again, please contact our distributor or us.

 

Q. Can I test blood glucose from sites other than my fingertips?

A. FORA® blood glucose meter systems allow you to obtain a blood sample from an alternative site such as your palm, forearm, upper arm, calf, or thigh.

Notice: alternative site test is not fit for everyone, it may have some limitations if you have just taken insulin and:
• You think your blood glucose is low.
• The test results do not agree with how you feel.
• You have an ill feeling.
• You are unaware of symptoms when you become hypoglycemic.
• Alternative site results may be different than those from the fingertips when blood glucose levels are changing rapidly, such as after a meal or during and after exercise.

 